The thermal oil heaters is our main product, she answers the following regulation
- European directive 97-23-CE
- Codes of conception EN-13445, AD-Merkblätter, ASME...
- Regulation on devices pressure and Technical Complementary Instructions of the Department of Industry and energy
- Spanish regulation UNE 9-310 on the "Installations with transmission of heat by means of a liquid different than water"
- German regulation DIN-4754 on the « Installations with transmission of heat »
- Regulations "Safety in machines"
In these moments we are making the fifth generation of thermal oil heater, with a combustion chamber designed to guarantee low emission of NOx and yields half-close 90 %.
STANDARD COMPONENTS
- Thermal oil pump Allweiler
- Burner Weishaupt
- Electric switchboard with PLC and touch screen Telemecanique
- Pression transmitter Telemecanique
- Cap Ari
MAIN CHARACTERISTICS
- Product range from 0,1 till 15 MW
- Vertical execution
- Two coils, three fumes pitch
- Nameplate pressure: 7bar
- Proof pressure: 16bar
- Nameplate temperature: 300ºC
OPTIONS
- Horizontal execution
- Nameplate pressure: 20bar
- Nameplate temperature: 400ºC
- Reclining gates
- Teleprocessing
- Admission N2 or fire-fighting
- Execution ATEX
- Executions « CUSTOM »